948 resultados para blood component therapy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Various reasons, such as ethical issues in maintaining blood resources, growing costs, and strict requirements for safe blood, have increased the pressure for efficient use of resources in blood banking. The competence of blood establishments can be characterized by their ability to predict the volume of blood collection to be able to provide cellular blood components in a timely manner as dictated by hospital demand. The stochastically varying clinical need for platelets (PLTs) sets a specific challenge for balancing supply with requests. Labour has been proven a primary cost-driver and should be managed efficiently. International comparisons of blood banking could recognize inefficiencies and allow reallocation of resources. Seventeen blood centres from 10 countries in continental Europe, Great Britain, and Scandinavia participated in this study. The centres were national institutes (5), parts of the local Red Cross organisation (5), or integrated into university hospitals (7). This study focused on the departments of blood component preparation of the centres. The data were obtained retrospectively by computerized questionnaires completed via Internet for the years 2000-2002. The data were used in four original articles (numbered I through IV) that form the basis of this thesis. Non-parametric data envelopment analysis (DEA, II-IV) was applied to evaluate and compare the relative efficiency of blood component preparation. Several models were created using different input and output combinations. The focus of comparisons was on the technical efficiency (II-III) and the labour efficiency (I, IV). An empirical cost model was tested to evaluate the cost efficiency (IV). Purchasing power parities (PPP, IV) were used to adjust the costs of the working hours and to make the costs comparable among countries. The total annual number of whole blood (WB) collections varied from 8,880 to 290,352 in the centres (I). Significant variation was also observed in the annual volume of produced red blood cells (RBCs) and PLTs. The annual number of PLTs produced by any method varied from 2,788 to 104,622 units. In 2002, 73% of all PLTs were produced by the buffy coat (BC) method, 23% by aphaeresis and 4% by the platelet-rich plasma (PRP) method. The annual discard rate of PLTs varied from 3.9% to 31%. The mean discard rate (13%) remained in the same range throughout the study period and demonstrated similar levels and variation in 2003-2004 according to a specific follow-up question (14%, range 3.8%-24%). The annual PLT discard rates were, to some extent, associated with production volumes. The mean RBC discard rate was 4.5% (range 0.2%-7.7%). Technical efficiency showed marked variation (median 60%, range 41%-100%) among the centres (II). Compared to the efficient departments, the inefficient departments used excess labour resources (and probably) production equipment to produce RBCs and PLTs. Technical efficiency tended to be higher when the (theoretical) proportion of lost WB collections (total RBC+PLT loss) from all collections was low (III). The labour efficiency varied remarkably, from 25% to 100% (median 47%) when working hours were the only input (IV). Using the estimated total costs as the input (cost efficiency) revealed an even greater variation (13%-100%) and overall lower efficiency level compared to labour only as the input. In cost efficiency only, the savings potential (observed inefficiency) was more than 50% in 10 departments, whereas labour and cost savings potentials were both more than 50% in six departments. The association between department size and efficiency (scale efficiency) could not be verified statistically in the small sample. In conclusion, international evaluation of the technical efficiency in component preparation departments revealed remarkable variation. A suboptimal combination of manpower and production output levels was the major cause of inefficiency, and the efficiency did not directly relate to production volume. Evaluation of the reasons for discarding components may offer a novel approach to study efficiency. DEA was proven applicable in analyses including various factors as inputs and outputs. This study suggests that analytical models can be developed to serve as indicators of technical efficiency and promote improvements in the management of limited resources. The work also demonstrates the importance of integrating efficiency analysis into international comparisons of blood banking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plasticized poly(vinyl chloride) (pPVC), although a major player in the medical field, is at present facing lot of criticism due to some of its limitations like the leaching out of the toxic plasticizer, di ethylhexyl phthalate (DEHP) to the medium and the emission of an environmental pollutant,dioxin gas,at the time of the post use disposal of PVC Products by incineration. Due to these reasons, efforts are on to reduce the use of pPVC considerably in the medical field and to find viable alternative materials. The present study has been undertaken in this context to find a suitable material for the manufacture of medical aids in place of pPVC. The main focus of this study has been to find out a non-DEHP material as plasticizer for pPVC and another suitable material for the complete repalcement of pPVC for blood/ blood component storage applications.Two approaches have been undertaken for this purpose-(1)the controversial plasticizer, DEHP has been partially replaced by polymeric plasticizers(2) an alternative material, namely, metallocene polyolefin (mPO) has been used and suitably modified to match the properties of flexible PVC used for blood and blood component storage applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated critical thresholds for fresh frozen plasma (FFP) and platelet (PLT) to packed red blood cell (PRBC) ratios and determined the impact of high FFP:PRBC and PLT:PRBC ratios on outcomes in patients requiring massive transfusion (MT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hemolytic anemia and vasoocclusion are the cardinal clinical features of sickle cell anemia. Vasoocclusion is a complex process involving not only the polymerization of deoxygenated sickle hemoglobin tetramers, but also interactions between sickle erythrocytes, vascular endothelium, platelets, leukocytes, and plasma proteins. The increased adherence of sickle erythrocytes to endothelium has been implicated as an early step in vasoocclusion. Other researchers have focused on leukocytes and platelets which might also contribute to disturbed blood flow. Microvascular occlusion results in acute painful crises, whereas macrovascular occlusion seems to be the cause of organ failure. The anemia results from the markedly shortened circulatory survival of sickle erythrocytes, together with a limited erythropoietic response. The erythropoiesis increases intensively, but it is not enough to balance the increased rate of erythrocytes destruction to maintain normal levels of total erythrocytes and hemoglobin concentrations; mainly by the low oxygen affinity of hemoglobin S and increased 2,3-Diphosphoglycerate. It is very difficult to separate processes leading to anemia or to vasoocclusion. Understanding the involvement of multiple blood componentes in vasoocclusion may elucidate the clinical manifestations and complications of sickle cell anemia, and may give new insights into the preventive and curative therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contaminating tumour cells in apheresis products have proved to influence the outcome of patients with multiple myeloma (MM) undergoing autologous stem cell transplantation (APBSCT). The gene scanning of clonally rearranged VDJ segments of the heavy chain immunoglobulin gene (VDJH) is a reproducible and easy to perform technique that can be optimised for clinical laboratories. We used it to analyse the aphereses of 27 MM patients undergoing APBSCT with clonally detectable VDJH segments, and 14 of them yielded monoclonal peaks in at least one apheresis product. The presence of positive results was not related to any pre-transplant characteristics, except the age at diagnosis (lower in patients with negative products, P = 0.04). Moreover, a better pre-transplant response trended to associate with a negative result (P = 0.069). Patients with clonally free products were more likely to obtain a better response to transplant (complete remission, 54% vs 28%; >90% reduction in the M-component, 93% vs 43% P = 0.028). In addition, patients transplanted with polyclonal products had longer progression-free survival, (39 vs 19 months, P = 0.037) and overall survival (81% vs 28% at 5 years, P = 0.045) than those transplanted with monoclonal apheresis. In summary, the gene scanning of apheresis products is a useful and clinically relevant technique in MM transplanted patients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Murine models with modified gene function as a result of N-ethyl-N-nitrosourea (ENU) mutagenesis have been used to study phenotypes resulting from genetic change. This study investigated genetic factors associated with red blood cell (RBC) physiology and structural integrity that may impact on blood component storage and transfusion outcome. Forward and reverse genetic approaches were employed with pedigrees of ENU-treated mice using a homozygous recessive breeding strategy. In a “forward genetic” approach, pedigree selection was based upon identification of an altered phenotype followed by exome sequencing to identify a causative mutation. In a second strategy, a “reverse genetic” approach based on selection of pedigrees with mutations in genes of interest was utilised and, following breeding to homozygosity, phenotype assessed. Thirty-three pedigrees were screened by the forward genetic approach. One pedigree demonstrated reticulocytosis, microcytic anaemia and thrombocytosis. Exome sequencing revealed a novel single nucleotide variation (SNV) in Ank1 encoding the RBC structural protein ankyrin-1 and the pedigree was designated Ank1EX34. The reticulocytosis and microcytic anaemia observed in the Ank1EX34 pedigree were similar to clinical features of hereditary spherocytosis in humans. For the reverse genetic approach three pedigrees with different point mutations in Spnb1 encoding RBC protein spectrin-1β, and one pedigree with a mutation in Epb4.1, encoding band 4.1 were selected for study. When bred to homozygosity two of the spectrin-1β pedigrees (a, b) demonstrated increased RBC count, haemoglobin (Hb) and haematocrit (HCT). The third Spnb1 mutation (spectrin-1β c) and mutation in Epb4.1 (band 4.1) did not significantly affect the haematological phenotype, despite these two mutations having a PolyPhen score predicting the mutation may be damaging. Exome sequencing allows rapid identification of causative mutations and development of databases of mutations predicted to be disruptive. These tools require further refinement but provide new approaches to the study of genetically defined changes that may impact on blood component storage and transfusion outcome.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to conduct an in vitro evaluation, by scanning electron microscopy (SEM), of the adhesion of blood components on root surfaces irradiated with Er,Cr:YSGG (2.78 mu m) or Er:YAG (2.94 mu m) laser, and of the irradiation effects on root surface morphology. Sixty samples of human teeth were previously scaled with manual instruments and divided into three groups of 20 samples each: G1 (control group) - no treatment; G2 - Er,Cr:YSGG laser irradiation; G3 - Er:YAG laser irradiation. After performing these treatments, blood tissue was applied to 10 samples of each group, whereas 10 samples received no blood tissue application. After performing the laboratory treatments, the samples were observed under SEM, and the resulting photomicrographs were classified according to a blood component adhesion scoring system and root morphology. The results were analyzed statistically (Kruskall-Wallis and Mann Whitney tests, alpha = 5%). The root surfaces irradiated with Er:YAG and Er,Cr:YSGG lasers presented greater roughness than those in the control group. Regarding blood component adhesion, the results showed a lower degree of adhesion in G2 than in G1 and G3 (G1 x G2: p = 0.002; G3 x G2: p = 0.017). The Er:YAG and Er,Cr:YSGG laser treatments caused more extensive root surface changes. The Er:YAG laser treatment promoted a greater degree of blood component adhesion to root surfaces, compared to the Er,Cr:YSGG treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Despite recent trends to decrease allogeneic red blood cell (RBC) transfusion thresholds, such transfusions remain an important supportive and life-saving intervention for neonatal intensive care patients. In neonates, apart from concerns about transfusionassociated infections, many controversial questions regarding transfusion practices remain unanswered. Moreover, neonates present specific clinical and immunologic characteristics that require selected blood component products. This article addresses many of these issues from a medical perspective, with emphasis on the best blood banking techniques to provide RBC products for neonatal transfusions. Copyright © 2011 by the American Academy of Pediatrics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Volume I, with the title, The logistics of blood transfusion therapy, is the proceedings of the first two symposia presented in 1974-75; volume II is the proceedings of the 1977 conference.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Signatures: A⁶ B-R⁸ S⁶

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and Objectives  In Australia, the risk of transfusion-transmitted malaria is managed through the identification of ‘at-risk’ donors, antibody screening enzyme-linked immunoassay (EIA) and, if reactive, exclusion from fresh blood component manufacture. Donor management depends on the duration of exposure in malarious regions (>6 months: ‘Resident’, <6 months: ‘Visitor’) or a history of malaria diagnosis. We analysed antibody testing and demographic data to investigate antibody persistence dynamics. To assess the yield from retesting 3 years after an initial EIA reactive result, we estimated the proportion of donors who would become non-reactive over this period. Materials and Methods  Test results and demographic data from donors who were malaria EIA reactive were analysed. Time since possible exposure was estimated and antibody survival modelled. Results  Among seroreverters, the time since last possible exposure was significantly shorter in ‘Visitors’ than in ‘Residents’. The antibody survival modelling predicted 20% of previously EIA reactive ‘Visitors’, but only 2% of ‘Residents’ would become non-reactive within 3 years of their first reactive EIA. Conclusion  Antibody persistence in donors correlates with exposure category, with semi-immune ‘Residents’ maintaining detectable antibodies significantly longer than non-immune ‘Visitors’.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The coagulation system of newborn infants differs markedly from that of older children and adults. The activities of most coagulation factors and anticoagulants are low, leading to altered regulation in the formation of the key enzyme, thrombin. Timely and adequate generation of thrombin is essential, as thrombin activates platelets and many coagulation factors, cleaves fibrinogen into fibrin and activates the antithrombotic and anti-inflammatory protein C pathway. On the other hand, excess thrombin may promote thrombotic complications and exacerbate harmful inflammatory reactions. Despite the characteristic features, the newborn coagulation system can be considered physiological, since healthy newborns rarely show haemorrhagic or thrombotic complications. Sick newborns, however, often encounter clinical situations that challenge their coagulation system. The aim of this study was to clarify the behaviour of the neonatal coagulation system in selected clinical situations, with a special emphasis on the generation of thrombin. Thrombin was measured by in vivo thrombin generation markers and by thrombin generation potential in vitro. The patient groups included sick newborns undergoing intensive care and receiving fresh-frozen plasma (FFP), requiring exchange transfusions (ET) or presenting with a congenital heart defect requiring open heart surgery. Additionally, healthy newborns with inherited heterozygous factor V Leiden (FVL) mutation were studied. Thrombin generation potential was also analysed in cord plasma of healthy infants and in adults. Healthy as well as sick newborn infants showed lower total thrombin generation potential in vitro but faster initiation of thrombin generation than adults. These findings were qualitatively similar when plasma was supplemented with platelets. Platelets, however, significantly altered the effect of the major anticoagulant, activated protein C (APC), on thrombin generation potential. In accordance with previous studies, thrombin generation in healthy newborn platelet-poor plasma was resistant to the anticoagulant effects of APC, but when the plasma was supplemented with platelets APC attenuated thrombin generation significantly more in newborns than in adults. In vivo generation of thrombin was elevated in nearly all of the sick newborn infants. The low-volume FFP transfusion as opposed to the change from neonatal to adult blood in ET exerted markedly different effects on neonatal thrombin generation. FFP reduced the in vivo generation of thrombin in those newborns with the highest pretransfusional thrombin generation, thus acting as an anticoagulant agent. In those infants with lower pretransfusional thrombin generation, the effect of FFP on thrombin generation was fairly neutral. On the other hand, the combination of red blood cells and FFP, used to perform ET, significantly increased the in vivo thrombin formation and shifted the balance in the newborn coagulation system to the procoagulant direction. Cardiopulmonary bypass (CPB) also significantly increased the in vivo thrombin generation, but the thrombin generation profile during CPB differed from that previously observed in adults. Escalation of thrombin at early reperfusion was not observed in newborns; in adults, its occurrence is associated with postoperative myocardial damage. Finally, in healthy newborns with FVL heterozygosity, faster initiation of thrombin generation was observed compared with controls. Interestingly, FV level was lower in FVL-heterozygous infants, possibly to counteract the procoagulant effects induced by FVL. In conclusion, unique features regarding thrombin regulation in newborn infants were observed. These features included a novel platelet effect on the regulation of the protein C pathway. The clinical challenges mainly seemed to shift the balance in the coagulation system of newborns to the procoagulant direction. Blood component transfusions markedly affected coagulation in a manner specific to the product but that could also be altered by the clinical situation. Overall, the results highlight the need for understanding developmental haemostasis for both diagnostic and therapeutic purposes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND. Laboratory data suggest that insulin-like growth factor-1 (IGE-1) may stimulate the growth of different human tumors. At least in acromegalic patients, somatostatin (SMS) analogs, such as lanreotide, suppress the serum levels of growth hormone (GH) and IGE-1. METHODS. To evaluate the tolerability and biologic activity of different doses of lanreotide in patients with advanced colorectal carcinoma, consecutive groups of 3 patients each were subcutaneous treated with lanreotide at doses of 1, 2, 3, 4, 5, or 6 mg three times a day for 2 months. In the event of Grade 3 side effects, 3 additional patients were treated with the same dose before the next dose escalation. Serum samples were obtained on Days 0, 15, 30, and 60 for serum GH, IGF-1, and lanreotide assessment. RESULTS. Twenty-four patients were enrolled and all were evaluable. Except for the 3 and 6 mg doses, for which the observation of a Grade 3 side effect required that an additional three patients be treated, it was sufficient to treat 3 patients at each dose. The overall incidence of side effects was as follows: changes in bowel habits, 83%; abdominal cramps, 79%; diarrhea, 17%; vomiting, 17%; nausea, 21%; steatorrhea, 78%; hyperglycemia, 35%; laboratory hypothyroidism, 39%; gallstones, 13%; and weight loss, 17%. No evidence of an increase in the incidence, intensity, or duration of side effects was observed with dose escalation. Serum IGF-1 levels were as follows: Day 13: 63%, 60%, and 67% of the baseline values for the low (12 mg), intermediate (3-4 mg), and high (5- 6 mg) dose groups, respectively; Day 30: 63%, 59%, and 51%, respectively; and Day 60: 73%, 69%, and 47%, respectively. Serum lanreotide levels declined during treatment in all of the dose groups (90 ng/mL on Day 15, and 35 ng/mL on Day 60 for the 5-6 mg group; 10 ng/mL on Day 15, and 1.5 ng/mL on Day 60 for the 1-2 mg group). No antitumor activity or tumor marker reduction was observed. CONCLUSIONS. No increase in toxicity was observed when subcutaneous lanreotide doses were escalated to 6 mg three times a day for 2 months. The highest doses seemed to maintain reduced serum IGF-1 levels; with the lowest doses, a 'rebound' in serum IGF-1 levels was observed during treatment. Nevertheless, intermittent subcutaneous injections do not ensure constant serum drug concentrations over time.